Zeiss Stratus 3000 OCT (2004)

Zeiss Stratus 3000 OCT (2004)


The standard of care system for comprehensive retina and glaucoma management.

  • Manufacturer

    Zeiss

  • Model

    Stratus 3000 OCT

Zeiss Stratus 3000 OCT

  • incl. Monitor
  • incl. Table
  • incl. Printer

Specifications
Tomographic Imaging
•Purpose: Cross sectional imaging of fundus
•Signal Type: Optical scattering from tissue
•Signal source: Super Luminescent Diode (SLD), 820 nm
•Optical Power: ≤ 750 microwatts at cornea. SLD current will shut off if a safety circuit is activated (upon scanner failure)
•Spot Size at Retina: 20 μm in tissue
•Longitudinal/Axial Resolution: ≤ 10 μm in tissue
•Transverse Resolution: 20 μm in tissue
•Scanners: Galvanometric mirrors
•Scan Patterns: Repeat, Line, Circle, Raster Lines, Cross Hair, Radial Lines, Macular Thickness Map, Optic Disc, Proportional Circle, Concentric 3 Rings, RNFL Thickness (3.4), Nerve Head Circle, RNFL Thickness (2.27xdisc), X-Line, RNFL Map, Fast Macular Thickness Map, Fast Optic Disc, Fast RNFL Thickness (3.4), Fast RNFL Map
•Scan Pixels: Adjustable from 131,072 to 786,432 (1024 longitudinal x 128 to 768 transverse)
•Scan Speed: 400 A-scans per second
•Scan Acquisition Time: Approx. 0.32 seconds (128 A-scans minimum.) to approx. 1.92 seconds (768 A-scans maximum.)
•Longitudinal (Depth) Scan Range: 2 mm in tissue

Fundus Imaging
•Purpose: Fundus alignment for tomographic imaging
•Signal Type: CCD image
•Field of View: 26° (horizontal) x 21° (vertical)
•Focus Adjustment Range: -12 to +20 D (diopters)
•Viewing Method: 15" Color Flat Panel Display
•Illumination: Halogen Lamp
•Internal Fixation: 32 × 16 Green LED dot matrix
•External Fixation: Slit lamp type adjustable blinking LED

Electrical Requirements
•Single phase:
100/120V~ systems:(± 10%), 50/60Hz, 6A
220/240V~ systems:(± 10%), 50/60Hz, 3A
•Power consumption: 700VA

Environmental Conditions
Transport and Storage
Temperature:-40 to +70 deg. C
Relative Humidity:10% to 100%, including condensation
Atmospheric Pressure:500 hPa to 1060 hPa

Operation
Temperature:+10 to +40 deg. C
Relative Humidity:30% to 75%, excluding condensation
Atmospheric Pressure:700 hPa to 1060 hPa

Physical Dimensions
Fits in a cubic space of 83 cm (depth) x 119 cm (length) x 125 cm (nominal height with 30 cm of table travel) (33 in x 48 in x 50 in).

System Weight
Complete system: 58.6 kg (129 lbs.), comprises Patient Module 24.5 kg (54 lbs.), computer 21.3 kg (47 lbs.), monitor 5.4 kg (12 lbs.), printer 6.4 kg (14 lbs.), keyboard and mouse 0.91 kg (2 lbs.).

Table Loading Capacity
The instrument table is specifically designed for use only with the original Stratus OCT system components installed in their original configuration. In this original configuration, the table loading capacity is 63.3 kg (139.5 lbs.) ± 5%.