Dräger Fabius GS

Dräger Fabius GS


High performance Anesthesia-Unit from Dräger

  • Manufacturer

    Dräger

  • Model

    Fabius GS

Dräger Fabius GS

A unit to meet all the needs of the clinicians with efficient and effective patient care. The Dräger Fabius GS allows you to add modular elements, so you will have all the function available in one machine. This means that the Fabius grows with your needs or concentrates on its main objective: taking care of the patient.

It is electrically driven and controlled, working without drive gas, so it is more flexible and efficient to use than conventional anesthesia units.  It is the first machine to work with vertical flow controls and electronic fresh gas flow indicators. By using this the clinician can control gas flows easily. 

Your future anesthesia unit comes from Dräger.

Weight (base unit without vaporizers or cylinders) 224 lbs (101.6 kg)

Dimensions (W X H X D) 35.2 x 51.2 x 32.3 inches (89.5 x 130 x 82 cm)

Power supply 100 - 240 VAC, 50/60 Hz, 2.3 A max.

Operation time with fully charged batteries up to 120 minutes, minimum 45 minutes

Ventilator E-vent Electronically controlled, electrically driven

Operating Modes

Standard:
Manual / Spontaneous
Volume Control (Volume)
Options:
Pressure Control (Pressure)
Pressure Support (PS)
Synchronized Volume
Controlled Ventilation w/PS (SIMV/PS)

Breathing frequency 4 to 60 1/min

Max. Minute volume (MV) 99 L/min

Positive end-expiratory pressure (PEEP) 0 - 20 cmH2O

Inspiration / Expiration ratio (Ti:Te) 4 : 1 to 1 : 4

Pressure limiting (Pmax) 15 - 70 cmH2O

Tidal Volume (Vt) 20 - 1400 mL in Volume Control 20 - 1100 mL in SIMV/PS

Inspiratory pause (Tip:Ti) 0 - 50 %

SIMV Inspiratory time (Tinsp) 0.3 - 4.0 sec

Inspiratory pressure (Pinsp) PEEP + 5 to 65 cmH2O

Inspiratory flow (InspFlow) 10 - 75 L/min in Volume and Pressure Control 10 - 85 L/min in Pressure Support

Pressure Support Level (Ä PPS) PEEP + 3 to 20 cmH2O

Min. Frequency for 3 - 20 1/min and “OFF” Apnea-Ventilation (Freq. Min.)

Trigger 2 - 15 L/min

Integrated safety functions

Sensitive Oxygen Ratio Controller (S-ORC) guarantees
a minimum O2concentration of 23% in an O2/N2O mixture. N2O cut-off if O2fresh gas valve is closed or if O2 flow is less than 0.2 L/min. Audible and visual (flashing red LED) indication in case O2pressure drops below 20 psi
(1.38 bar) ± 4 psi (0.27 bar).
In case of electricity and battery failure, manual
ventilation, gas delivery and agent delivery are possible. Positive pressure relief valve opens at 75 ± 5 cmH2O. Negative pressure relief valve opens at - 7.5 to - 9 cmH2O

Range of fresh gas flow indicators 0.00 to 12.0 L/min

Total fresh gas flow meter 0 to 10 L/min, calibrated with a mixture of 50 % O2 and 50 % N2 0 mixture

O2 flush at 87 psi (6 bar): max. 75 L/min at 41 psi (2.8 bar): min 25 L/min

Vaporizer Mount 2 position Dräger mount 2 position Selectatec

Control Screen 6,5” (16,5cm) black/amber

Monitoring Continuous monitoring of inspiratory O2concentration, breathing frequency, tidal volume, minute volume, mean or

plateau pressure, peak airway pressure as well as PEEP. In addition, all fresh gas flow information is displayed as virtual flow tubes.

Serial interface 1 x RS 232 (standard) 2nd RS 232 port (option)

Protocols Vitalink and Medibus

Data available for export All fresh gas flow, ventilation and O2 data

Volume of CO2 absorber 1.5 Liter,
Option: Dräger Medical’s prefilled CLIC absorber (1,2 l)

Gas Supply O2, N2O & Air

Cylinder yokes O2, N2O, Air, pin index yokes

Additional accessories Gas scavenging, patient suction, power outlet strip, additional O2flow tube

Volume of entire compact breathing system 1.7 Liter + bag